Specifications

o LIGHT Zone: LIGHT and light setting level is displayed
o FAN Zone: Blank
o TIME/PROG Zone: Current day indicator, current time, and Program status (P1-
OFF or P2-OFF) is displayed
o AUX Zone: AUX and AUX setting is displayed
o FLAME Zone: Blank
Program ON LCD Displays:
o THERMO ON:
THERMO and ON will flash (~0.5 seconds on & ~0.5 seconds off) for
15-seconds, then THERMO & ON will be displayed continuously.
o THERMO OFF: THERMO and OFF is displayed.
o ROOM TEMP Zone: Measured temperature is displayed
o SET TEMP Zone: SET TEMP is displayed
o LIGHT Zone: LIGHT and light setting level is displayed
o FAN Zone:
If Thermostat is ON, FAN and fan setting number is displayed
If Thermostat is OFF, display is blank.
o TIME/PROG Zone: Current day indicator, current time, and Program status (P1-
ON or P2-ON) is displayed
o AUX Zone: AUX and AUX setting is displayed
o FLAME Zone:
If Thermostat is ON, Flame-A and Flame-B Icons and flame setting level
numbers are displayed.
If Thermostat is OFF, display is blank.
Program Disable Feature
The Program Mode (described above) may be disabled for applications where a program
operation is not allowed or undesirable. When Program Mode is Disabled:
o The user will not be able to activate Program Mode
o The user will not be able to enter Program Setup or edit Program Mode settings.
o The TIME/PROG zone will continue to display the Clock and Day of week, but
none of the icons associated with Program Mode will be displayed.
To disable or re-enable the Program Mode, the transmitter must be in MANUAL OFF
Mode, then press and hold the TIME/PROG Zone and the DOWN Button simultaneously
for 10-seconds. The LCD screen will go blank except either PROGRAM and OFF (OFF
display in MODE Zone) or PROGRAM and ON (ON display in MODE Zone) will flash
3-times (0.5-seconds OFF, 0.5-seconds ON) to indicate the change has been made.
Flame-A (or Main) Adjustment
Transmits a flame height setting command to the control module to adjust the Flame-A
height.
Available settings are 1-3 with a factory default of 3. If the Flame-A setting is changed
during operation (either manually or automatically), the control will remember and use
the adjusted setting on subsequent manual ON cycles (Flame-A setting memory). Refer
to the THERMOSTAT Mode section for additional details on flame modulation in
THERMOSTAT mode.
While in MANUAL ON, THERMOSTAT ON, or PROGRAM ON modes, press the
FLAME Zone to enter Flame-A Adjustment, then press the UP or DOWN buttons to
raise and lower the flame; press the MODE/SET Button or wait for 15 seconds to accept
the new setting.