Specifications
o LIGHT Zone: LIGHT and light setting level is displayed
o FAN Zone: Blank
o TIME/PROG Zone: Current day indicator, current time, and Program status (P1-
OFF or P2-OFF) is displayed
o AUX Zone: AUX and AUX setting is displayed
o FLAME Zone: Blank
• Program ON LCD Displays:
o THERMO ON:
▪ THERMO and ON will flash (~0.5 seconds on & ~0.5 seconds off) for
15-seconds, then THERMO & ON will be displayed continuously.
o THERMO OFF: THERMO and OFF is displayed.
o ROOM TEMP Zone: Measured temperature is displayed
o SET TEMP Zone: SET TEMP is displayed
o LIGHT Zone: LIGHT and light setting level is displayed
o FAN Zone:
▪ If Thermostat is ON, FAN and fan setting number is displayed
▪ If Thermostat is OFF, display is blank.
o TIME/PROG Zone: Current day indicator, current time, and Program status (P1-
ON or P2-ON) is displayed
o AUX Zone: AUX and AUX setting is displayed
o FLAME Zone:
▪ If Thermostat is ON, Flame-A and Flame-B Icons and flame setting level
numbers are displayed.
▪ If Thermostat is OFF, display is blank.
Program Disable Feature
• The Program Mode (described above) may be disabled for applications where a program
operation is not allowed or undesirable. When Program Mode is Disabled:
o The user will not be able to activate Program Mode
o The user will not be able to enter Program Setup or edit Program Mode settings.
o The TIME/PROG zone will continue to display the Clock and Day of week, but
none of the icons associated with Program Mode will be displayed.
• To disable or re-enable the Program Mode, the transmitter must be in MANUAL OFF
Mode, then press and hold the TIME/PROG Zone and the DOWN Button simultaneously
for 10-seconds. The LCD screen will go blank except either PROGRAM and OFF (OFF
display in MODE Zone) or PROGRAM and ON (ON display in MODE Zone) will flash
3-times (0.5-seconds OFF, 0.5-seconds ON) to indicate the change has been made.
Flame-A (or Main) Adjustment
• Transmits a flame height setting command to the control module to adjust the Flame-A
height.
• Available settings are 1-3 with a factory default of 3. If the Flame-A setting is changed
during operation (either manually or automatically), the control will remember and use
the adjusted setting on subsequent manual ON cycles (Flame-A setting memory). Refer
to the THERMOSTAT Mode section for additional details on flame modulation in
THERMOSTAT mode.
• While in MANUAL ON, THERMOSTAT ON, or PROGRAM ON modes, press the
FLAME Zone to enter Flame-A Adjustment, then press the UP or DOWN buttons to
raise and lower the flame; press the MODE/SET Button or wait for 15 seconds to accept
the new setting.