display in MODE Zone) or PROGRAM and ON (ON display in MODE Zone) will flash
3-times (0.5-seconds OFF, 0.5-seconds ON) to indicate the change has been made.
Flame-A (or Main) Adjustment
• Transmits a flame height setting command to the control module to adjust the Flame-A
height.
• Available settings are 1-3 with a factory default of 3. If the Flame-A setting is changed
during operation (either manually or automatically), the control will remember and use
the adjusted setting on subsequent manual ON cycles (Flame-A setting memory). Refer
to the THERMOSTAT Mode section for additional details on flame modulation in
THERMOSTAT mode.
• While in MANUAL ON, THERMOSTAT ON, or PROGRAM ON modes, press the
FLAME Zone to enter Flame-A Adjustment, then press the UP or DOWN buttons to
raise and lower the flame; press the MODE/SET Button or wait for 15 seconds to accept
the new setting.
• LCD Display: When setting the Flame-A height, the Flame-A icon, and Flame-A setting
number will flash in the FLAME Zone.
Flame-B (or Rear) Adjustment
• Transmits a flame height setting command to the control module to adjust the Flame-B
height.
• Available settings are 0 (off) – 3 with a factory default of 3. If the user changes the
Flame-B setting during operation, the control will remember and use the adjusted setting
on subsequent manual ON cycles (Flame-B setting memory).
• While in MANUAL ON, THERMOSTAT ON, or PROGRAM ON modes, press the
FLAME Zone twice enter Flame-B Adjustment (first press is Flame-A adjustment), then
press the UP or DOWN buttons to raise and lower the flame; press the MODE/SET
Button or wait for 15 seconds to accept the new setting.
• LCD Display: When setting the Flame-B height, the Flame-B icon, and Flame-B setting
number will flash in the FLAME Zone.
Flame-B Adjustment Disable Feature
• The Flame-B Adjustment Feature (described above) may be disabled for applications
where secondary flame adjustment is not used. When Flame-B Adjustment is Disabled:
o The Flame-B Icon and setting number will not be displayed.
o No adjustment to the Flame-B setting can be made.
• To disable or re-enable the Flame-B Adjustment, the transmitter must be in MANUAL
OFF Mode, then press and hold the FLAME Zone and the DOWN Button simultaneously
for 10-seconds. The LCD screen will go blank except either the FLAME-B Icon and OFF
(OFF display in MODE Zone) or the FLAME-B Icon and ON (ON display in MODE
Zone) will flash 3-times (0.5-seconds OFF, 0.5-seconds ON) to indicate the change has
been made.