User's Manual

display in MODE Zone) or PROGRAM and ON (ON display in MODE Zone) will flash
3-times (0.5-seconds OFF, 0.5-seconds ON) to indicate the change has been made.
Flame-A (or Main) Adjustment
Transmits a flame height setting command to the control module to adjust the Flame-A
height.
Available settings are 1-3 with a factory default of 3. If the Flame-A setting is changed
during operation (either manually or automatically), the control will remember and use
the adjusted setting on subsequent manual ON cycles (Flame-A setting memory). Refer
to the THERMOSTAT Mode section for additional details on flame modulation in
THERMOSTAT mode.
While in MANUAL ON, THERMOSTAT ON, or PROGRAM ON modes, press the
FLAME Zone to enter Flame-A Adjustment, then press the UP or DOWN buttons to
raise and lower the flame; press the MODE/SET Button or wait for 15 seconds to accept
the new setting.
LCD Display: When setting the Flame-A height, the Flame-A icon, and Flame-A setting
number will flash in the FLAME Zone.
Flame-B (or Rear) Adjustment
Transmits a flame height setting command to the control module to adjust the Flame-B
height.
Available settings are 0 (off) – 3 with a factory default of 3. If the user changes the
Flame-B setting during operation, the control will remember and use the adjusted setting
on subsequent manual ON cycles (Flame-B setting memory).
While in MANUAL ON, THERMOSTAT ON, or PROGRAM ON modes, press the
FLAME Zone twice enter Flame-B Adjustment (first press is Flame-A adjustment), then
press the UP or DOWN buttons to raise and lower the flame; press the MODE/SET
Button or wait for 15 seconds to accept the new setting.
LCD Display: When setting the Flame-B height, the Flame-B icon, and Flame-B setting
number will flash in the FLAME Zone.
Flame-B Adjustment Disable Feature
The Flame-B Adjustment Feature (described above) may be disabled for applications
where secondary flame adjustment is not used. When Flame-B Adjustment is Disabled:
o The Flame-B Icon and setting number will not be displayed.
o No adjustment to the Flame-B setting can be made.
To disable or re-enable the Flame-B Adjustment, the transmitter must be in MANUAL
OFF Mode, then press and hold the FLAME Zone and the DOWN Button simultaneously
for 10-seconds. The LCD screen will go blank except either the FLAME-B Icon and OFF
(OFF display in MODE Zone) or the FLAME-B Icon and ON (ON display in MODE
Zone) will flash 3-times (0.5-seconds OFF, 0.5-seconds ON) to indicate the change has
been made.