• Program ON LCD Displays:
o MODE Zone: THERMO and either ON or OFF is displayed
o ROOM TEMP Zone: Measured temperature is displayed
o SET TEMP Zone: SET TEMP is displayed
o LIGHT Zone: Blank
o FAN Zone: Blank
o TIME/PROG Zone: Current day indicator, current time, and Program status (P1-
ON or P2-ON) is displayed
o AUX Zone: Blank.
o FLAME Zone:
If Thermostat is ON, the Flame-A Icon is displayed.
If Thermostat is OFF, display is blank.
Flame Adjustment
• Transmits either a HI command or a LO command to the control module to adjust the
flame height.
• While in MANUAL ON, THERMOSTAT ON, or PROGRAM ON modes, press the
FLAME Zone to enter Flame Adjustment, then press the UP or DOWN buttons to raise
and lower the flame. This command is transmitted at the same time the user is pressing
the UP or DOWN Button.
• LCD Displays: When in Flame-A adjustment mode, the Flame-A icon will flash in the
FLAME zone; when actually adjusting the flame, the direction of adjustment (HI or LO)
will be displayed:
o When raising the flame height with the UP button, the FLAME-A Icon and HI
will flash in the FLAME Zone.
o When lowering the flame height with the DOWN button, the FLAME-A Icon
and LO will flash in the FLAME Zone.
Continuous Pilot Operation
• To activate or deactivate the Continuous Pilot Feature, press and hold the MODE/SET
and UP Buttons simultaneously for 5 seconds.
• LCD Display: When activated, CONT. PILOT will be displayed in the MODE Zone.
Child-Lock Operation
• Child-Lock operation prevents any user input to the transmitter. No mode of operation or
feature may be adjusted when Child-Lock is activated. All automatic functions
(thermostat, program, etc.) will continue normally.
• To activate or deactivate the Child-Lock feature, press and hold the MODE/SET and
DOWN Buttons simultaneously for 5 seconds.
• LCD Display:
o When activated, the LOCK icon will appear in the MODE Zone.
o If any touch-zone or button is pressed when activated, the LCD backlight will
illuminate and the LOCK icon will flash for 5 seconds in the MODE Zone.
Communication Safety
• In manual ON, thermostat and program modes of operation, the transmitter will send a
communication safety transmission every 15-minutes. This signal is further processed by
the ignition control module to verify the transmitter is communicating properly.
Room Temperature Limit