User's Manual

o FAN Zone: Blank
o TIME/PROG Zone: Current day indicator and current time is displayed
o AUX Zone: Blank
o FLAME Zone: Blank
THERMOSTAT ON LCD Displays:
o MODE Zone: THERMO and ON are displayed
o ROOM TEMP Zone: Measured temperature is displayed
o SET TEMP Zone: SET TEMP is displayed
o LIGHT Zone: Blank
o FAN Zone: Blank
o TIME/PROG Zone: Current day indicator and current time is displayed
o AUX Zone: Blank
o FLAME Zone: The FLAME-A Icon is displayed
Thermostat Disable Feature
The Thermostat Mode (described above) may be disabled for applications where a
thermostat is not allowed or undesirable. When Thermostat Mode is Disabled:
o The Modes of operation will cycle between MANUAL ON and MANUAL OFF
(omitting THERMO).
o Program Operation (described below) is also disabled.
o The SET TEMP zone will be blank.
o The room temperature will still be measured & displayed in the ROOM TEMP
Zone.
o The TIME/PROG zone will continue to display the Clock and Day of week, but
none of the icons associated with Program Mode will be displayed.
To disable or re-enable the Thermostat, the transmitter must be in MANUAL OFF Mode,
then press and hold the SET TEMP Zone and the DOWN Button simultaneously for 10-
seconds. The entire contents of the LCD screen will flash 3-times (0.5-seconds OFF, 0.5-
seconds ON) to indicate the change has been made.
Program Operation
Press the TIME/PROG Zone to activate or deactivate Program Operation. Pressing the
MODE Zone or the MODE/SET Button will also deactivate Program Operation. When
Program Operation is deactivated, the transmitter will return to MANUAL OFF Mode.
Program Operation will cycle fireplace ignition ON and OFF based on time settings (2
weekend periods and 2 weekday periods) and thermostat settings. Reference program
operation for current production model 5301P for complete description of operation and
factory defaults. Press the MODE/SET Button or wait for 15 seconds to advance to each
subsequent program setting.
To enter Program Setup, press and hold the TIME/PROG Zone for 5 seconds.
Program OFF LCD Displays:
o MODE Zone: OFF
o ROOM TEMP Zone: Measured temperature is displayed
o SET TEMP Zone: Blank
o LIGHT Zone: Blank
o FAN Zone: Blank
o TIME/PROG Zone: Current day indicator, current time, and Program status (P1-
OFF or P2-OFF) is displayed
o AUX Zone: Blank
o FLAME Zone: Blank