User's Manual
o SET TEMP Zone: Blank
o LIGHT Zone: Blank
o FAN Zone: Blank
o TIME/PROG Zone: Current day indicator and current time is displayed
o AUX Zone: Blank
o FLAME Zone: Blank
MANUAL ON Mode:
• Transmits flame ON command
• LCD Displays:
o MODE Zone: ON is displayed
o ROOM TEMP Zone: Measured temperature is displayed
o SET TEMP Zone: Blank
o LIGHT Zone: Blank
o FAN Zone: Blank
o TIME/PROG Zone: Current day indicator and current time is displayed
o AUX Zone: Blank
o FLAME Zone: the FLAME-A Icon is displayed
THERMOSTAT Mode:
• Will cycle flame on and off based on room and set temperatures. Will transmit ON
command if SET TEMP (+SWING) is higher than ROOM TEMP and will transmit OFF
command if SET TEMP (-SWING) is lower than ROOM TEMP.
• Built-in thermostat will measure room temperature.
• All programming should be written for deg. F scale and converted to deg. C when
selected.
• Temperatures may be displayed in degrees F (factory default) or degrees C. Press the UP
and DOWN Buttons simultaneously to change between degrees F and C.
• SET TEMP: While in THERMOSTAT mode, press the UP or DOWN Button to change
the SET TEMP (45-99 deg. F, 7-37 deg. C); the new set temperature will automatically
be accepted after 2 seconds. The factory default SET TEMP is 45 deg. F.
• SWING Temperature:
o Factory default is 2 degrees F (1 deg. C).
o Press and hold the SET TEMP Zone for 5 seconds to enter SWING Adjustment,
and press the UP and DOWN Buttons to adjust the SWING temperature from 3
degrees F (2 degrees C) or to 1 deg. F (still 1 deg. C) (press the MODE/SET
Button or wait for 15 seconds for the new setting to be accepted).
o LCD Display - When in SWING Adjustment:
MODE Zone: Blank
ROOM TEMP Zone: Blank
SET TEMP Zone: S1, S2, or S3 (number equals swing temperature) in
place of the SET temperature
LIGHT Zone: Blank
FAN Zone: Blank
TIME/PROG Zone: Blank
AUX Zone: Blank
FLAME Zone: Blank
• THERMOSTAT OFF LCD Displays:
o MODE Zone: THERMO and OFF is displayed
o ROOM TEMP Zone: Measured temperature is displayed
o SET TEMP Zone: SET TEMP is displayed
o LIGHT Zone: Blank