MANUAL FUNCTION
Initial Setup
Hold SET and UP buttons simultaneously for 5 seconds to enter set-up. Each function scale setting is
changed by “UP” or “DOWN” key.
Setting of C/F conversion:
C/F conversion: Use UP or DOWN key to choose Celsius or Fahrenheit, Press "SET" button to continue to
gas type setup.
Setting of Swing Scale:
Swing Scale: Use UP of DOWN key to change the swing value (1° to 3°F (1° to 2°C), Press "SET" button
to continue to clock set up.
Clock Setup:
Use UP of DOWN key to select the day of the week.
Use UP or DOWN key to set HOUR, then press SET to enter “Minute” setting.
Use UP or DOWN key to set “Minute”, and then press SET to enter AM/PM setting.
Use UP or DOWN key to set AM/PM, the press SET to enter day of week setting.
Mode
To operate the system in the manual “MODE” does the following.
ON OPERATION
Press the “MODE” key into the ON mode. The appliance flame and fan will come on. During this
time the screen will show ON. All the functions could be chosen that MAIN FLAME/ REAR FLAME /
FAN/ LIGHT/ AUX/ TIMER /Program, will be active.
THERMO OPERATION
Press the “MODE” key into the THERMO mode. The transmitter will check the ROOM temperature
and SET temperature to decide the situation THERMO ON or THERMO OFF. After 2 seconds the LCD
screen will display the situation by temperature detected that is comparing with the SWING temperature
scale.
OFF OPERATION