Operation Manual

B. 1. 3. AUTO PROGRAM
All the functions are available in AUTO PROGRAM, except the programming function. Once AUTO
PROGRAM was selected, the PB-4-DMX will be run under all the program one by one, i.e. P01-16,
preset in MANUAL PROGRAM.
B. 1. 4. HOLD SOUND
The performance of the light will depends on the input sound.
B. 1. 5. PROG SOUND
The selected program will be run by the input sound.
B. 1. 6. AUTO SOUND
The preset programs will be run from P01 to P16.
B. 2. F + D/S BUTTONS ( Press F and D/S buttons at a time )
Press to select CRO or NOR.
NOTE : NOR refers to 0-100% dimming.
CRO denotes only FULL ON and STAND BY are available. When dimming level is greater
than 50%.
FULL ON is activated, otherwise, STAND BY is effective.
B. 3. F + BUTTON ( Press F and buttons at a time )
Press to select L-- or R--.
NOTE : L-- refers to data information of CH1, CH2, CH3 and CH4 corresponding to 1, 2, 3 and 4
output.
R-- refers to data information of CH1, CH2, CH3 and CH4 corresponding to 4, 3, 2 and 1
output.
B. 4. F + SIGNAL SELECT + RESET BUTTONS
Press to perform a reset for the whole system, which enables to return to initial condition.
B. 5. MASTER indicator blinks when preheat is effective.
B. 6. SIGNAL indicator goes out in master modus.
B. 7. FULL ON & STAND BY ( Located on the remote control 154.068 )
FULL ON and STAND BY are effective only in MASTER mode. Press FULL ON to activate full on
function of whole channel output, DISPLAY shows FUL. Press STAND BY to turn off whole channel,
and STD appears.
B. 8. DISPLAY shows OUT and channel indicators don’t blink after 10 seconds when operation is paused.