<2>Place two optical fibers in the fusion splicer.
Both Arc Calibration Fibers and Splicing Fibers are made in exactly the same
way.
9. ARC Calibration ( Video: youtu.be/lBO6tsaLN5k)
Why do we need to do Arc Calibration?
When the fiber optic material, altitude, climate, temperature, humidity,
electrode condition and other factors change greatly, it may lead to increased
splicing loss of the l splicer; Arc calibration can effectively reduce the splicing
loss.It is recommended to do an ARC calibration before the first use after getting
the machine.
<1>Select “Arc Calibration” from the main menu page
<3>Closing the cover will automatically start the arc calibration.
<4>If “Step1: Arc Calibration Not Finished” or “Step2: Arc Calibration
Not Finished ” is displayed at the bottom of the screen, it indicates that the
calibration has failed. Please make two fibers again, then start Arc Calibration
again.