User Guide

6
6
ESSENTIAL PRE-OPERATING PROCEDURES
BEFORE OPERATING YOUR SKYE MACHINE FOR THE FIRST TIME, THE FOLLOWING
PROCEDURES MUST BE CARRIED OUT.
Your new unit is already in a vacuum. The storage tank(s) must be evacuated prior to use.
Set Up Procedure: (REFER TO THE ILLUSTRATED LAYOUT ON PAGE 5.)
1. Open both the tank valves to vent the factory nitrogen charge (if any), close the LIQUID
VALVE and place the tank on the scale platform. Connect the tank float lead.
2. Feed both service hoses and the power cord through the hole in the side panel. Connect
the RED 96” service hose to the HIGH SIDE PORT and to the VAPOR VALVE on the
storage tank. (Check tank valve handles for correct port identification - DO NOT GO
BY COLOR.)
3. Connect the machine to power.
4. Turn the FUNCTION SELECTOR to the VACUUM position, open the BLUE and RED
MANIFOLD VALVES and turn the VACUUM PUMP SWITCH ON. Evacuate the storage
tank and machine for a minimum of 20 minutes. While evacuating remove the 2 fan shroud
screws nearest the side panel hole and install the HOSE HANGER using the same screws.
5. When the vacuum is complete, turn the FUNCTION SELECTOR to the CLOSED position,
CLOSE BOTH MANIFOLD VALVES and the TANK VAPOR VALVE then turn the
VACUUM PUMP OFF. Disconnect the red service hose from the tank.
6. Disconnect the hose from the LOW SIDE PORT and connect it to the TANK VAPOR PORT
then open the tank vapor valve. Connect the BLUE 96” service hose to LOW SIDE PORT.
7. Connect the liquid charging/utility hose to a bottle of R12 containing at least 10 lbs. of R12
and to the RECYCLE INLET PORT, open the valve on the bottle, turn it upside down for
liquid and set it down in front of the machine. Press the scale keypad ON button, allow
warm-up, then press the ZERO button for 2 seconds. Turn the FUNCTION SELECTOR to
the RECOVER position, press the RECOVER ON button. The scale LCD will start counting
up as refrigerant flows into the tank.
8. When 10 to 12 lbs. of refrigerant is in the tank, close the valve on the R12 bottle and allow
the machine to stop automatically. Turn the FUNCTION SELECTOR (FS) to the CLOSED
position and press the RECOVER OFF button. Remove the hose from the R12 bottle and
Recycle Inlet Port then connect it to the tank liquid port and the Liquid Charging Port . If
the machine is not going to be used immediately, disconnect power.
YOUR MACHINE IS NOW READY FOR USE.
TO RECOVER VAPOR OR LIQUID REFRIGERANT