User Guide

5
5
Your SUPERSKYE EP6 is designed for vapor and/or liquid refrigerant RECOVERY/
RECYCLING, VACUUM and RECHARGE of systems containing R12 or R134a.
DO NOT LAY THE UNIT DOWN -- THIS WILL CAUSE LOSS OF VACUUM PUMP OIL.
The EP6 unit comes with:
1 x 96" R12 Red service hose with ABB on one end.
1 x 96" R12 Blue service hose with ABB on one end.
1 x 96" R134a Red service hose with Service Adapter on one end.
1 x 96" R134a Blue service hose with Service Adapter on one end.
2 x 30 lb. (14.6 Kg) Dual valve storage tanks with floats. (1 x R12, 1 x R134a)
2 x 8 oz. (240 cc) Oil measuring bottles. (1 x oil drain, 1 x oil charge)
2 x 32" R12 tank hoses with ABB on both ends.
2 x 32" R134a tank hoses with ABB on both ends.
1 x Temperature probe with 10’ lead.
1 x Set of clutch voltage probes with 48” leads. (1 x Red, 1 x Black)
1 x 8 oz. (240 cc) Bottle of Vacuum Pump Oil.
EP6 CONTROL MENU LAYOUT
BUTTON BAR
BUTTON BAR
BUTTON BAR
REFRIGERANT SELECTED
MAIN SKYE
MENU
REFRIGERANT SELECTED
MENU 4 SKYE
DISPLAY
AUTO RECOVER VACUUM
MENU
2
REFRIGERANT SELECTED
MENU 2 SKYE
CHARGE NCG
CHECK
RECOVERED
OIL DRAIN
CHANGE
GAS
MENU
3
REFRIGERANT SELECTED
MENU 3
SKYE
CHANGE
FILTER
SET
UP
FLUSH HELP MENU
4