User Guide

27
27
Improper operation allowing
pressure to be vented through
vacuum pump.
Solenoid valve malfunction.
Call SKYE at 1-800-722-7593.
Call SKYE at 1-800-722-7593.
Unit will not turn on. Power not connected.
Using heat blanket switch not
master power switch.
Fuse blown.
Check connection/power source.
Verify correct switch is used.
Check/replace fuse.
Change Gas displays check for leak
message and will not complete
change operation.
Hoses connected to machine
incorrectly. Hose leaking or port(s)
not capped. Missing hose gasket.
Tank liquid valve open.
Check hose connection orientation.
Cap hose port(s). Replace hose
gasket & Schrader depressor.
Close tank liquid valve.
Motor will not run. Float lead not connected.
High pressure trapped in machine.
Check/connect float lead.
Call SKYE at 1-800-722-7593.
For technical difficulties not
mentioned -
Call SKYE at - 1-800-722-7593
TEMPERATURE/PRESSURE
COMPARISON CHART
º F
º C
R12
PSIG
KPa
R134a
PSIG
KPa
R22
PSIG
KPa
FR12
PSIG
KPa
Freezone
&
Freeze 12
PSIG
Kpa
º F
º C
R12
PSIG
KPa
R134a
PSIG
KPa
R22
PSIG
KPa
FR12
PSIG
KPa
Freezone
&
Freeze 12
PSIG
KPa
-40
-40
-11
-75.8
-14.8
-120
0.6
4.1
-16.2
-111.7
-16.3
-112.4
85
29
92
634.3
95.2
656.4
155.7
1073.5
83
572.3
84.5
582.6
-35
-37
-8.4
-57.9
-12.5
-86.2
2.6
17.9
-14.1
-97.2
-14.2
-97.9
90
32
100.1
690.2
104.3
719.1
168.4
1161.1
91
627.4
92.8
639.8
-30
-34
-5.5
-37.9
-9.9
-68.3
4.9
33.8
-11.7
-80.7
-11.8
-81.4
95
35
108.6
748.8
113.9
785.3
181.8
1253.5
99.5
686
101.5
699.8
-25
-32
-2.3
-15.9
-6.9
-47.6
7.4
51
-9.1
-62.7
-9.2
-63.4
100
38
117.5
810.1
124.1
855.6
195.9
1350.7
106.6
735
110.7
763.2