Check vacuum pump oil level regularly. Oil should be present on the tip of the dipstick. Add
oil through the vent/dipstick tube as necessary. Change vacuum pump oil at least monthly to
maintain optimum performance. Use SKYE part # 276030 only.
The machine will notify the user when the filter life has expired. Follow the on screen
instructions for changing the filter.
The electronics and other features of this machine are not user serviceable. Call SKYE for
technical support at 1-800- 722-7593.
TROUBLESHOOTING TIPS
SYMPTOM POSSIBLE CAUSE SOLUTION
Machine resets to main menu
during recovery operation.
Storage tank vapor valve closed.
Storage tank hoses connected
improperly.
Hose anti-blowback valve
malfunction.
Solenoid valve malfunction.
Storage tank full.
Open tank vapor valve.
Check and correct hose
connections.
Check/repair ABB valve.
Call SKYE at 1-800-722-7593
Change tank.
Oil spray from vacuum pump vent
tube.
Vacuum pump overfilled.
Improper oil charge operation
resulting in a vacuum pump overfill
condition.
Drain and refill with correct amount.
Drain and refill with correct amount.