User Guide

25
25
Press the EXIT button to return to the main menu.
UPDATE PROCEDURE
This procedure will only be used when updating the operating program and data base in your
SuperSKYE machine. Specific installation instructions will be provided with the update
information. When the UPDATE button in menu 4 is pushed the following screen will be
displayed.
Upon receipt of an update, it will be necessary to load the update onto a desktop or notebook
computer with Windows 95 or 98 and link that computer to the SuperSKYE machine. When an
update is ready to be installed in the machine, press the UPDATE button and double click the
update icon on your computer’s desktop. The screen will display the loading process and
return to the main menu when the process is complete.
If there is more than one program to be updated, there will be multiple icons on your desktop.
It will be necessary to repeat the full procedure for each program. Once all updates have been
loaded, disconnect from the base computer and turn your SuperSKYE machine off for at least
15 seconds. When your SuperSKYE is turned on, the new information will be in effect. If you
encounter problems in the update process, call 1-800-722-7593 for assistance.
ADDITIONAL FEATURES
DUCT TEMPERATURE PROBE
The duct temperature probe provides outlet air temperature information for the
technician. This feature can be useful in identifying plenum and other air flow problems.
In addition, the probe can be used to measure temperatures on inlet and outlet points of
system components.
CLUTCH VOLTAGE
IMPORTANT: THE CLUTCH VOLTAGE TEST IS POLARITY SENSITIVE. THE RED
LEAD CONNECTS TO THE HOT (POWER) SIDE AND THE BLACK LEAD
CONNECTS TO THE NEGATIVE (GROUND) SIDE.
The clutch voltage feature provides an actual clutch voltage indication. The screen will
display the DC voltage at the clutch within 1 VDC.
EQUIPMENT SERVICE & MAINTENANCE
Refrigerant Selected
SKYE
MAIN
MENU
UPDATE