Press the buttons to set the charge amount then press the GO button to start the charge.
The machine will charge the AC system until the full amount has been charged or the system
pressure equalizes. If the charge completes, the machine will automatically go to the next
screen. If pressure equalizes before the charge completes, press the EXIT button to proceed
to the next screen.
Press the DONE button to initiate the recovery process. When the recovery process has been
completed the next screen will be displayed.
Press and hold the DRAIN OIL button until all the recovered oil has been drained. When you
are finished draining the oil press the EXIT button to go to the next screen.
If you want to change refrigerant, press the YES button and the machine will start the change
gas procedure. If you do not want to change gas, press the NO button to initiate the internal
pump down and return to the main menu.
HELP PROCEDURE
The HELP selection provides useful information on refrigerant capacity and retrofit procedures.
When selected the following screen displays.
SYSTEM
INFORMATION & GUIDE
Tank Wgt ______lbs _____oz
Lo ________ Hi _______
Charge Wgt ____ ____
USE DOUBLE NORMAL CHARGE
GO
EXIT
Amount Charged ______lbs _____oz
Close tank liquid valve
Charge Complete (Aborted)
DONE
Tank Wgt ______lbs _____oz
Lo ________ Hi _______
Charge Wgt ____ ____
USE DOUBLE NORMAL CHARGE
GO
EXIT
CURRENT REFRIGERANT IS R_____
Change Refrigerant
YES NO