4.0 Specifications
Frequency of
Operation:
L Band transmit and receive
Transmit EIRP: < 2 Watts
Dimensions: 9 5/8" x 7" x 1"
244.48 mm x 177.8 mm x 25.4mm
Power: Batteries: Internal: 8 "AA" lithium primary batteries
External: Regulated 6 volt vehicle power
Automatic sensing and switching of external power
Weight
(w/batteries):
3 lb
Operating
Temperature:
-40 Deg C to 70 Deg C
Storage
Temperature:
-55 Deg C to 85 Deg C
Vibration: 2 G rms, MIL-STD-810D, Method 514.4
Shock: 30 G, MIL-STD-810D, Method 516.3, Procedure I
Salt Fog: General Motors Engineering Standards Corrosion Test
GM-9505P for a duration of five weeks
Humidity: 100% Condensing
Water Immersion: 1 Meter, 30 Minutes
Interface: 15 Pin Connector
2 open/closed switch connections
2 open/closed control lines
RS-485 Interface
Mounting: Stainless Steel Mounting Bracket Bonded to Trailer Roof
With 3M VHB Tape
Table 1 Specifications