Installation Instructions

2
POWER CONFIGURATIONS
Prior to installing your SkyBell, make sure your home is
compaible with one of the power coniguraions listed.
Power coniguraion diagrams are available at
www.skybell.com/support/power.
Unless otherwise indicated, all power coniguraions require
primary power (110/120 VAC in the US and 220/230/240 VAC,
in Europe) and a low-voltage
transformer (10-36V 10 VA).
1. A MECHANICAL DOOR CHIME AND LOW VOLTAGE
TRANSFORMER (Recommended).
2. A DIGITAL DOOR CHIME WITH ADAPTER AND A LOW
VOLTAGE TRANSFORMER.
4. Router Band - SkyBell will only connect to the 2.4 GHz
band. If you have a dual-band router, you must create unique
SSIDs for the 2.4 and 5 GHz bands. Prior to iniiaing the
syncing process, make sure your mobile device is connected to
the 2.4GHz SSID.
5. Router b/g/n - SkyBell works on the b/g network. If you
have an “N-Only” router, please acivate the b/g seing.
6. Router Channel Bandwidth - Make sure your router is
conigured to 20 MHz bandwidth.
7. Transformer - If your SkyBell is being powered by your
home’s transformer, the transformer’s output must be between
10 and 36 VAC 10 VA.
5
6