User guide

29
PART VIII : AUXILIARY FUNCTIONS
8.9 Changing Polar Scope Illumination Level
8.10 Identifying Objects
H.C. Firmware: The rmware version of the SynScan hand control.
Database: The database version of the SynScan hand control
H.C. Hardware: The hardware version of the SynScan hand control.
Motor Controller: The rmware version of the motor controller of the mount.
H.C. Serial #: The serial number of the SynScan hand control.
This function applies only to certain Sky-Watcher’s equatorial mounts that are equipped with
a polar scope illuminator.
1. Access the menu “UTILITY FUNCTION \ Polar Scope LED” and press the ENTER key.
2. Use the Left/Right direction keys to adjust the illumination level. Press the ENTER key to
conrm and exit.
After aligning the mount, the SynScan hand control can be used to identify the object to which
the telescope is pointing.
1. Center the object to be identied in the telescope’s eyepiece.
8.7 Display Polaris Position
8.6 Display Power Voltage
8.8 Display Polar Alignment Error
Access the menu “UTILITY FUNCTION \ Show Information \ Polaris Pos.” and press the ENTER
key, and then use the scroll keys to switch the screen display between “Polaris Position in P.
Scope = HH:MM”. and “Hour Angle of Polaris = HH:MM“. Press the ESC key to exit.
Access the menu “UTILITY FUNCTION \ Show Information \ Power Voltage” and press the ENTER
key to display the power voltage applied to the mount. Press the ESC key to exit.
Access the menu “UTILITY FUNCTION \ Show Information \ P.A Error” and press the ENTER key.
The screen will display “Mel=+DDD
o
MM’SS Maz=+DDD
o
MM’SS”. The “Mel” value is the polar
alignment offset in elevation, and the “Maz” value is the polar alignment offset in azimuth.
These data is valid only after a 2-star alignment or a 3-star alignment.