Install Instructions
9
Attach the L-shaped bracket to the top/front of the humidier, so that the 4.
vertical wall is toward the reservoir.
Adjust the water level. (See Nos. 7 & 8 in “Plumbing and Setting the Water 5.
Level”, pgs. 11 & 12.)
Slide the anges of the humidier reservoir into the mounting bracket until 6.
the reservoir’s front ange comes in contact with the edge of the duct.
Secure the humidier to the duct with the screws provided. 7.
Option B requires a transition to be
made, and usually needs duct reinforce-
ment to hold the humidier securely in
place.
NOTE: For this conguration, the humidi-
er is mounted on the outside of the ple-
num, rather than the inside, so as not to
restrict airow.
DANGER: Wear safety glasses when
cutting or drilling. Do not cut or drill into
any air conditioning components or electri-
cal enclosures during installation. Elec-tro-
cution is possible if you come in contact
with a live electrical wire; blindness can
occur if refrigerant contacts your eyes.
To install (Option B):
Construct a transition and attach it to 1.
the plenum. (Additional humidier sup-
port will be necessary for this congura-
tion.)
Place the mounting bracket (provided) at the base of the transition. 2.
Use a marker to trace around the inside of the mounting bracket. Cut out 3.
the duct opening.
CAUTION: DO NOT attach the mounting bracket before the hole in the
ductwork has been cut.
Attach the L-shaped bracket to the top/front of the humidier, so that the 4.
vertical wall is toward the reservoir.
Figure 3—Option B:
External Side Mount
Figure 4—Mounting Bracket