Install Instructions

6
For the Contractor: How To Install
a Skuttle Model 60-Series Steam Humidier
NOTES: This humidier must be installed by a qualied professional
contractor. Failure to comply with this requirement may nullify the
warranty.
Read all instructions before beginning installation of the humidier. Skut-
tle Manufacturing Company assumes no responsibility under warranty if the
contractor and user do not follow these printed instructions.
FOR WIRING INSTRUCTIONS AND INSTALLATION OF THE ELECTRONIC
COMPENSATING HUMIDISTAT, PLEASE SEE SEPARATE INSTRUCTIONS
ENCLOSED IN THE HUMIDIFIER CARTON.
Safety Precautions
Do not install a humidier where the surrounding temperature may exceed 1.
200°F.
CAUTION: Excessive heat will damage the humidier, possibly causing
an overow condition and water damage to the home.
Do not install a humidier where the surrounding temperature may be 32°F 2.
or colder (e.g., attics, garages, etc.).
CAUTION: Freezing water will damage the humidier and burst the sup-
ply pipe, resulting in damage to the home.
Do not cut or drill into any air conditioning components or electrical enclo-3.
sures during humidier installation.
DANGER: Electrocution is possible if you come in contact with a live
electrical wire; blindness can occur if refrigerant contacts your eyes.
When the humidier is installed in a nished basement or any area where 4.
water damage could occur, be sure to connect the humidiers overow
provision to a suitable drain.
For above-ceiling installations, install an additional drain pan plumbed to a 5.
suitable drain.
Installation, wiring and plumbing of the humidier must comply with local 6.
codes, ordinances and regulations.