User Guide

5
7. Clean all parts in a 50/50 solution of vinegar and water. (For stubborn
deposits, soak parts overnight.)
8. For reassembly, reverse Steps 1 through 6. To ensure proper humidier
operation, see “How to Check Your Humidier for Proper Operation”,
page 3.
Skuttle
®
Automatic Flushing Timer
Programmable Flushing of Reservoir and Steam Humidiers
Provides ow-thru technology for
reser voir and steam humidiers.
Automatically ushes the humidier
water pan with fresh, clean water
every two hours.
Programmable to 10-, 20- and
30-second ushes per cycle.*
Reduces or eliminates servicing
during the humidication season.
Uses minimal electricity; reduces water usage by up to 98 percent
when compared to conventional ow-thru units.
Quick and easy to install—usually less than 20 minutes.
Adaptable to any make or model of reservoir or steam humidier.
*Factory setting is for 10-second ushing cycle every two hours.
6. See the diagram below for disassembly and reassembly of the drum.