Install Instructions

Skuttle’s Model 60-BC1 is designed to be free
standing or connected to the duct. As a free-
standing unit, the humidier may be placed
on a nonammable (e.g., steel) shelf or table.
(See Figure 1, below.) It also may be hung from
exposed ceiling joists, as shown. (See Figure 2.)
INSTALLATION INSTRUCTIONS
Before installing the humidier, remove the
orange label and cardboard packing on and
around the grille.
Check and adjust the unit’s water level as
indicated in the installation manual.
If the unit is to be connected to the duct,
remove the inlet and outlet grilles to help
increase airow.
1.
2.
3.
To connect the unit to ridged ductwork, use
duct size 12˝ x 12˝ (30.48 x 30.48 cm) and
S-cleats.
Remove the outlet and intake grilles from the
humidifier.
Run the duct to a finished wall or floor, and
cut an opening to fit. Place a grille or diffuser
on the outlet. (If appropriate, do the same for
the intake side of the humidifier.)
CAUTION: In the event of a mechanical
malfunction, the humidifier could overflow. To
prevent water damage, connect the overflow
fitting to an appropriate drain.
4.
5.
6.
See Wiring Diagram (Figure 3)
on Back 
Supplementary Installation
Instructions for
Skuttle Model 60-BC1
Steam Humidier
NOTE: For plumbing, wiring, maintenance instructions
and replacement parts, refer to the 60-series installation
instructions manual, Installation Instructions for
Model 60-Series High-Capacity Steam Humidiers.
Figure 1: 60-BC1
Free Standing
Figure 2: 60-BC1
Connected to Duct

Summary of content (2 pages)