User Guide

11
Plumbing and Setting the Water Level
NOTE
: Use copper tubing only to plumb this humidifier.
1. Select the nearest cold water pipe and install the saddle connector and
needle valve (provided) by following the instructions supplied with the
valve.
WARNING
: Do not use any line connected to an air conditioner.
2. Lightly clean the tubing ends with fine sandpaper before making connections.
3. Uncoil the copper tubing and
connect one end to the saddle
valve. Use the compression fit-
tings found in the self-piercing
saddle valve parts bag.
Place the brass compression
nut over the tubing, then slide
the brass ferrule over the
tubing.
Fully insert the tubing into
the saddle valve fitting and
tighten the compression nut.
(Do not over-tighten; moderate tightness should prevent leaking.)
Thoroughly flush the supply tubing after attaching it to the saddle
valve. This will clear the line of debris which could block water flow at
the float valve.
4. Route the tubing to the humidifier float valve, keeping the tubing away
from sharp edges.
5. Connect the remaining end of the tubing to the humidifier float valve.
6. Open the saddle valve so that the water flows slowly and gently into the
water pan.
7. Prior to mounting, adjust the humidifier’s water level by following these
instructions:
Set the humidifier reservoir on a level surface.
Allow the unit to fill until the float valve shuts off the incoming flow of
water. (The water should be 2-3/8" deep, plus or minus 1/8". If it is not,
further adjustment will be necessary.)