4. Attach the L-shaped bracket to the top/front of the humidifier, so that the
vertical wall is toward the reservoir.
5. Adjust the water level. (See Nos. 7 & 8 in “Plumbing and Setting the Water
Level”, pgs. 11 & 12.)
6. Slide the flanges of the humidifier reservoir into the mounting bracket until
the reservoir’s front flange comes in contact with the edge of the duct.
7. Secure the humidifier to the duct with the screws provided.
Option B requires a transition to be
made, and usually needs duct reinforce-
ment to hold the humidifier securely in
place.
NOTE
: For this configuration, the humidi-
fier is mounted on the outside of the
plenum, rather than the inside, so as not
to restrict airflow.
DANGER
: Wear safety glasses when
cutting or drilling. Do not cut or drill into
any air conditioning components or electri-
cal enclosures during installation. Elec-
trocution is possible if you come in
contact with a live electrical wire; blind-
ness can occur if refrigerant contacts
your eyes.
To install (Option B):
1. Construct a transition and attach it to
the plenum. (Additional humidifier sup-
port will be necessary for this configu-
ration.)
2. Place the mounting bracket (provided) at the base of the transition.
3. Use a marker to trace around the inside of the mounting bracket. Cut out
the duct opening.
CAUTION
: DO NOT attach the mounting bracket before the hole in the
ductwork has been cut.
4. Attach the L-shaped bracket to the top/front of the humidifier, so that the
vertical wall is toward the reservoir.
Figure 3—Option B:
External Side Mount
Figure 4—Mounting Bracket