Figure 14- 1
Modules Diagram for the System Management
When system powering up, a “master” system manager will be elected among all line
cards existing in the chassis to control the whole equipment. The shelf manager con-
trol board sends/receives messages from the cards and modules over I
2
C bus. The
elected “master” system manager on the line card get information from the shelf
manager control board across the switch board by TCP/IP to control and monitor the
whole system.
Information Inquire
To restart the system when JadeOS is in trouble, use the following command:
reload
To inquire the system information such as JadeOS version, gateway uptime, and so on,
use the following command:
show version
To inquire chassis components status such as power module connection status, fan
speed, line card temperature and so on, use the following command:
show inventory
To inquire the factory default information about chassis, use the following command:
show chassis_info
To inquire the environment temperature about the chassis, use the following com-
mand:
show temperature chassis