User Manual
11
GFCI Unit (Fig. 3)
Your tool is equipped with a GFCI (ground
fault circuit interrupter) unit mounted on the
power cord.
Risk of electric shock.
Test before each use.
1. Plug GFCI unit into power outlet. Green indi-
cator light should turn on.
2. Press ‘TEST’ button. The indicator light
should turn off.
3. Press and release ‘RESET’ button. Green
indicator light should turn on.
Do not use the tool if the
indicator light fails to
turn on. GFCI unit may have a problem and
must be replaced. Have the tool serviced by
Bosch Factory Service Center or Authorized
Bosch Service Station.
Operating Instructions
Depth Adjustment (Fig. 4)
1. Disconnect plug from power source and
place the tool on a flat level surface.
2. Hold main handle with one hand and pull on
the lock latch (black tab) to release the peg.
Return tool to the full upright position.
3. Pull up the depth adjustment lever to loosen
the depth stop and slide depth stop to de-
sired depth. Align indicator line on depth
stop to desired depth on depth of cut brack-
et scale. Tighten depth of cut lever by push-
ing it down.
INDICATOR
LIGHT
GFCI UNIT
RESET
BUTTON
TEST
BUTTON
Fig. 3
MAIN HANDLE
DEPTH
ADJUSTMENT
LEVER
LOCK LATCH
PEG
INDICATOR
LINE
DEPTH
STOP
Fig. 4
CALIBRATED
DEPTH BRACKET
1619X09633.indd 11 10/7/16 3:58 PM