MSDS

Material Safety Data Sheet 2
5. FIRE FIGHTING MEASURES
Autoflammability Not applicable.
Flash point >250ºC
Extinguishing media CO
2
; Dry chemical.
Fire fighting procedures No special procedures are required.
Fire & Explosion hazards Not applicable.
Hazardous combustion Carbon monoxide, carbon dioxide, unknown
products hydrocarbons.
6. ACCIDENTAL RELEASE MEASURES
Spill or leakage: Allow to cool and solidify. Scrape up and
collect in suitable containers for disposal.
7. HANDLING AND STORAGE
Storage temperature Ambient.
Special sensitivity No special sensitivity.
Handling/storage Store in a cool, dry area.
Precaution: this product should only be
heated to recommended temperatures. The
hazards of pyrolysis products are unknown.
Ventilation requirements Local exhaust over glue chamber.
8. EXPOSURE CONTROL / PERSONAL PROTECTION
Ventilation: Local ventilation over glue chamber.
Respiratory protection: None required if good ventilation is maintained.
Eye protection: Safety glasses, goggles or face shield to
protect against splashing.
Hand protection: Thermally resistant gloves should be worn.
Clothing requirements Uniforms, coveralls, or a lab coat should be worn.
9. PHYSICAL AND CHEMICAL PROPERTIES
Pure substance or prep Preparation
Physical form Solid
Appearance/odour Amber; no odour
pH as is Not applicable
Boiling point >250ºC
Melting point 90 - 100ºC
Solubility in water Insoluble
Relative density 1.000