Owner manual

4
12. Place disposable items in resealable test packet bag,
seal, and dispose of as hazardous materials. See
Disposing on page 10.
Do not discard Step 1 We ing Agent solution,
spray nozzle, or bo le unless empty or expired.
Bo le contains enough solution for several
tests.
SKC recommends sealing the Step 1 solution bo le
with the provided screw cap for transport and storage.
Thoroughly wash exterior of bo le with soap and water before
sampling at another site to avoid cross contamination.
Using the MethChek 50 Wipe Kit (50 ng LLOI)
Preparing to Sample
See Cautions and Handling on pages 9-10 before proceeding.
1. Put on clean gloves supplied in kit.
Use new, clean gloves for each test.
2. Place wax paper and supplied items on a level
surface.
3. Place supplied template on test surface.
SKC recommends adhering template to surface.
Consult state meth sampling guidelines for
recommended template locations.
Multiple samples in multiple locations within a
structure are recommended. Consult state meth
sampling guidelines.
4. Remove screw cap from Step 1 We ing Agent
bo le. Insert and tighten spray nozzle. Prime
spray bo le in a waste can and then spray co on
swab tip 2 times at a distance of approximately
4 inches. Rotate tip between sprays.
Place template.
Spray 2 times with Step 1
Wetting Agent.
3
4
Place items on wax paper.
2
1212
Place disposable items in
resealable bag.