Instruction Manual
3
5. The LED at the port will light a steady red to indicate that a charge sequence
has been initiated.
If the LED does not light to red in < 60 seconds, see Troubleshooting,
Step 1.
6. Once the ba ery pack is fully charged, the LED at the port will change to a
steady green to indicate that PowerFlex has switched to a trickle charge to keep
the ba ery at full charge.
7. The ba ery can be removed at any time a er the LED turns green. Detach the
ba ery from the cable and remove the cable from the charger.
Important Note: Pumps may remain connected to the charger indefi nitely
(without causing damage to the pump or charger).
Important Note: Remove pump-specifi c cable from charger when not in
use to avoid shorting.
Troubleshooting
If the LED does not light when a ba ery pack is plugged into the port or the LED
does not turn off a er a ba ery pack is unplugged, follow the steps in the table.
Step Action No result, Action Yes result, Action
1 Keep the unit powered on. If the battery is
deeply discharged, the LED may take up to
30 minutes to light or turn off.
Go to Step 2 Proceed with operation
2 Move unit to a different wall outlet Go to Step 3 Proceed with operation
3 Unplug charger from its power source for
20 seconds. Plug it back into power source.
Go to Step 4 Proceed with operation
4 Replace pump-specifi c cable Go to Step 5 Proceed with operation
5 Try a different battery pack Call SKC Proceed with operation —
previous battery pack
may be damaged,
call SKC.