TECHNICAL FEATURES
Manufacturer: SISTEMATICA S.p.A.
Dimensions: 100x100x75
Outputs number: 2
IP protection: IP66
Operating temperature: -20°C ÷ +70°C
Power supply voltage: 12 V ±10%
Power supply voltage: 24 V ±10%
Current consumption (stanby): - 18 mA at 12 V
- 14 mA at 24 V
Protection of battery inversion polarity
Max current per channel: 5 A
Max total current: 7,5 A
Reverse battery protection
Internal antenna
Category receiver (EN 300-220-1): 2
SYSTEM CODING
Coding the system is an operation that is only necessary when the receiver has
to be replaced or you want to use it with a different SISTEMATICA radio remote
control from the one it is coupled with at the time of purchase.
1. For a correct coding procedure, perform the following steps:
2. Disconnect the power to the receiver;
3. Press one pushbutton on the right of the receiver box (figure 1);
4. Put power into the receiver by keeping the pushbutton pressed for 3-4 sec.;
so release the pushbutton;
5. Press any 3 keys at the same time on the transmitter within 15 seconds since
it has been switched on (also more time if it is necessary);
6. At this time, the transmitter is codified with the reveiver; check all the system
function by trying the movements of the system;
Figure 1. Pushbutton
POSITIONING OF THE RECEIVER UNIT, RECEIVER DIMENSION
For a proper functioning, locate the receiver type POWERDRIVE with the cable output to the left and the two button
to the right, as shown in the picture below:
The receiver is provided with an integrated antenna; be sure to locate it at sight, not inside any
metal box or screened by ferrous masses (ex. Protection carter...)
The dimensions of the drilling template are correct only with the box positioned as shown in the figure 2.
EXAMPLE OF POSITIONING OF RECEIVER UNIT
Figura 2. Drilling template
RECEIVER DIMENSION
Figura 3. Box dimensions