Turn-Up an
d
Testing 3EM21522AAAA
DTR-0200-SA-SIRIUS Issue 1, March 2008
4-8
Figure 4 - 8 Modulator Mode Screen
5
Set RF output power to +53.0 dBm, and measure the RF output power at
the junction box forward coupled jack, CPL FWR, with power meter. The
measured RF power level shall be within ±0.5 dB from the set RF power
level indicated on the GUI Global Status screen.
6
Remove the power meter from the FWD RF MONITOR connector.
No alarm shall be reported other than door(s) open.
4.5
CONNECT REPEATER SYSTEM TO NMC
Coordinate with NMC and place repeater in remote operating condition.