Testing 3EM21522AAAA
DTR-0200-SA-SIRIUS Issue 1, March 2008
4-2
4.3
REPEATER PROVISIONING
Provisioning is the process of checking, changing, and/or installing parameter values
to allow the repeater to operate from its assigned location. Normally, no parameter
changes will be required except after replacement of the SPU.
1
Turn on repeater power
2
Connect computer to repeater controller Ethernet port
3
Access repeater GUI
4
Set repeater to Standby mode
5
Provision Repeater (check, change, install parameters as indicated by GUI
screen readings and consistent with local network engineering require-
ments)
6
Return repeater to Broadcast mode
7
Connect repeater to NMC.
4.4
FIELD TESTS
The purpose of the field test is to verify that the repeater meets specifications after
on-site repair. The field test will be performed with the Ku-Band Receive Chain of the
specific site.
A field test report form is provided to record the operating conditions and critical per-
formance parameters of the repeater after repair. This report should be kept on file
and referred to whenever the repeater is retested (after maintenance
, etc.).
4.4.1
Test Set-Up
1
Remove power from repeater by opening repeater main power circuit
breaker on the PDU (see Figure 4 - 1).
Figure 4 - 1 PDU Circuit Breaker Panel