Figure 3 - 1 AC Wiring (Sheet 2 of 2)
DTR-1079
03/16/08
Notes:
1. The repeater must be powered directly from a 240v ac service panel with 40 amp UL listed circuit breakers.
2. The green ground wire is to be connected to a safety ground derived from a copper ground plane or rod.
3. A 4-conductor #8 power cable with rubber jacket rated at 90 C will be used.
4. The ac power wiring design and installation must conform to all local and national electrical codes.