User's Manual Part 1
Table Of Contents
- Instruction Book Introduction
- Customer Service
- Technical Assistance Center
- Sections 1-6
- Section 1 General
- Section 2 Functional Description
- 2.1 General
- 2.2 System Functional Overview
- 2.3 Main Functions
- 2.3.1 Signal Processing Unit (SPU) Sub-assembly
- Figure 2 - 2 Signal Processing Unit (SPU)
- Figure 2 - 3 Sirius Signal Processing Unit (SPU) Functional Block Diagram
- Figure 2 - 4 VSAT (L-Band) Receiver Panel
- Figure 2 - 5 Modulator Module
- Figure 2 - 6 Up-Converter Module Panel
- Figure 2 - 7 Controller Board Panel
- Figure 2 - 8 Main Controller Board Functional Block Diagram
- Figure 2 - 9 Uninterruptible Power Supply (UPS)
- 2.3.1 Signal Processing Unit (SPU) Sub-assembly
- 2.4 High Power Amplifier (HPA)
- 2.5 S-Band Output Filter
- 2.6 Output Coupler
- 2.7 Power Distribution
- 2.8 Junction Box Assembly
- Section 3 Installation
- 3.1 Introduction
- 3.2 Safety On Site
- 3.3 INSTALLATION OVERVIEW
- 3.4 SITE POWER
- 3.5 REPEATER UNPACKING AND INSPECTION
- 3.6 SUGGESTED TOOL LIST
- 3.7 ANTENNA INSTALLATION
- 3.8 REPEATER CABINET INSTALLATION
- 3.9 CABLE CONNECTIONS (see Figure 3 - 2)
- 3.10 POST-INSTALLATION INSPECTION/TEST
- 3.11 Post Installation Inspection/Test Form
- Section 4 Turn-Up and Testing
- 4.1 General
- 4.2 Test Equipment Required
- 4.3 Repeater Provisioning
- 4.4 Field Tests
- 4.5 Connect Repeater System to NMC
- 4.6 Field Test Report
- Section 5 Operation
- 5.1 GENERAL
- 5.2 Control and Communication
- 5.3 Modes of Operation
- 5.4 GRAPHICAL USER INTERFACE (GUI)
- 5.5 GUI Menu Descriptions
- 5.5.1 Status Sub-Menu Breakdown
- 5.5.2 Configuration (Config) Sub-Menu Breakdown
- Figure 5 - 7 GUI Main Menu Config Drop-Down Menu
- Figure 5 - 8 Config Modulator Sub-Menu
- Figure 5 - 9 Repeater ID Screen
- Figure 5 - 10 Modulator Mode Screen
- Figure 5 - 11 Overlay Screen
- Figure 5 - 12 Delays Screen
- Figure 5 - 13 Modulator IP Screen
- Figure 5 - 14 VSAT Screen
- Figure 5 - 15 Repeater Output Level Screen
- Figure 5 - 16 Coupler Screen
- Figure 5 - 17 GPS Screen
- Figure 5 - 18 Temperature Screen
- Figure 5 - 19 Repeater Operating Mode Screen
- Figure 5 - 20 PPP Dial In Parameters Screen
- Figure 5 - 21 PPP Dial Out Parameters Screen
- Figure 5 - 22 PPP Misc Parameters Screen
- Figure 5 - 23 Site Screen
- 5.5.3 Alarms Sub-Menu Breakdown
- 5.5.4 NMS Users Sub-Menu Breakdown
- 5.5.5 System Parameters Menu
- Figure 5 - 28 Access to System Parameters Sub-Menu
- Figure 5 - 29 System Parameters Identification Screen
- Figure 5 - 30 System Parameters Access Control Screen
- Figure 5 - 31 System Parameters Network Parameters Screen
- Figure 5 - 32 System parameters SNMP Parameters Screen
- Figure 5 - 33 System Parameters System Time Screen
- Figure 5 - 34 System Heartbeat Time Screen
- Figure 5 - 35 System Parameters System Reset Screen
- Figure 5 - 36 System Parameters Upgrade Screen
- Figure 5 - 37 Upgrade Dialog Box (Sheet 1 of 2)
- 5.6 COMMAND LINE INTERFACE (CLI)
- 5.7 REPEATER OPERATING PROCEDURES
- 5.8 CONTROLS, INDICATORS, and CONNECTORS
- 5.8.1 Signal Processing Unit (SPU) Controls and Indicators
- 5.8.2 High Power Amplifier (HPA) Controls and Indicators
- 5.8.3 Power Distribution Unit (PDU) Front Panel Controls
- 5.8.4 VSAT Receiver Rear Panel Connectors
- 5.8.5 Up-Converter Rear Panel Connectors
- 5.8.6 Modulator Rear Panel Connectors
- 5.8.7 Main Controller Rear Panel Connectors
3EM21522AAAA Insta
ll
ation
Issue 1, March 2008 DTR-0200-SA-SIRIUS
3-1
3 INSTALLATION
3.1
INTRODUCTION
This section describes the installation of Alcatel-Lucent’s Sirius Digital Terrestrial
Repeater, DTR-0200-SA-SIRIUS, Alcatel-Lucent part number 3EM04000AA and
associated antennas at a designated site. This equipment is to be installed in a
restricted access location.
3.2
SAFETY ON SITE
3.2.1
Installation Safety
Installation shall be performed by trained, qualified personnel. For installation and
wiring of the SIRIUS Terrestrial Repeater and associated antennas in the USA, the
installer will adhere to the applicable clauses of the National Electric Code and all
applicable local codes. For installation in Canada, the installer will adhere to the
applicable National Canadian Electric Code and all applicable local codes.
3.2.2
Grounding
Grounding will be in accordance with MOTOROLA STANDARDS AND GUIDE-
LINES FOR COMMUNICATION SITES, 68P81089E50-B, 9/1/05 — UP, local codes
and requirements
, SIRIUS requirements, and Alcatel-Lucent construction/installa-
tion drawings in the order stated. Ensure that the grounding wire of the wiring con-
duit is properly attached to the customer-supplied service panel ground bar.
3.2.3
Electrical Safety
1.
A readily accessible disconnect device shall be incorporated in the build-
ing installation wiring.
2.
A capital letter “N” located adjacent to an electrical terminal indicates
that terminal is intended exclusively for connection of the primary power
neutral conductor.
3.
Personnel will obey all safety/hazard/warning signs and labels.
4.
All repeater equipment electrical power must be off during installation.
5.
Ensure that the main power switch to the repeater equipment is turned
off and a “
DANGER-DO NOT TURN ON - Personnel Working” sign is hung
on the switch prior to working on internal parts of the repeater.
6.
Ensure that all repeater circuit breakers are turned off prior to working
on internal parts or connecting cables of the repeater.
7.
Ensure that the main power cable to the repeater PDU is the last cable
to be connected to the repeater when installing repeater cables.