User's Manual Part 1

Table Of Contents
3EM21522AAAA Insta
ll
ation
Issue 1, March 2008 DTR-0200-SA-SIRIUS
3-1
3 INSTALLATION
3.1
INTRODUCTION
This section describes the installation of Alcatel-Lucent’s Sirius Digital Terrestrial
Repeater, DTR-0200-SA-SIRIUS, Alcatel-Lucent part number 3EM04000AA and
associated antennas at a designated site. This equipment is to be installed in a
restricted access location.
3.2
SAFETY ON SITE
3.2.1
Installation Safety
Installation shall be performed by trained, qualified personnel. For installation and
wiring of the SIRIUS Terrestrial Repeater and associated antennas in the USA, the
installer will adhere to the applicable clauses of the National Electric Code and all
applicable local codes. For installation in Canada, the installer will adhere to the
applicable National Canadian Electric Code and all applicable local codes.
3.2.2
Grounding
Grounding will be in accordance with MOTOROLA STANDARDS AND GUIDE-
LINES FOR COMMUNICATION SITES, 68P81089E50-B, 9/1/05 — UP, local codes
and requirements
, SIRIUS requirements, and Alcatel-Lucent construction/installa-
tion drawings in the order stated. Ensure that the grounding wire of the wiring con-
duit is properly attached to the customer-supplied service panel ground bar.
3.2.3
Electrical Safety
1.
A readily accessible disconnect device shall be incorporated in the build-
ing installation wiring.
2.
A capital letter “N” located adjacent to an electrical terminal indicates
that terminal is intended exclusively for connection of the primary power
neutral conductor.
3.
Personnel will obey all safety/hazard/warning signs and labels.
4.
All repeater equipment electrical power must be off during installation.
5.
Ensure that the main power switch to the repeater equipment is turned
off and a
DANGER-DO NOT TURN ON - Personnel Working sign is hung
on the switch prior to working on internal parts of the repeater.
6.
Ensure that all repeater circuit breakers are turned off prior to working
on internal parts or connecting cables of the repeater.
7.
Ensure that the main power cable to the repeater PDU is the last cable
to be connected to the repeater when installing repeater cables.