User's Manual Part 1
Table Of Contents
- Instruction Book Introduction
- Customer Service
- Technical Assistance Center
- Sections 1-6
- Section 1 General
- Section 2 Functional Description
- 2.1 General
- 2.2 System Functional Overview
- 2.3 Main Functions
- 2.3.1 Signal Processing Unit (SPU) Sub-assembly
- Figure 2 - 2 Signal Processing Unit (SPU)
- Figure 2 - 3 Sirius Signal Processing Unit (SPU) Functional Block Diagram
- Figure 2 - 4 VSAT (L-Band) Receiver Panel
- Figure 2 - 5 Modulator Module
- Figure 2 - 6 Up-Converter Module Panel
- Figure 2 - 7 Controller Board Panel
- Figure 2 - 8 Main Controller Board Functional Block Diagram
- Figure 2 - 9 Uninterruptible Power Supply (UPS)
- 2.3.1 Signal Processing Unit (SPU) Sub-assembly
- 2.4 High Power Amplifier (HPA)
- 2.5 S-Band Output Filter
- 2.6 Output Coupler
- 2.7 Power Distribution
- 2.8 Junction Box Assembly
- Section 3 Installation
- 3.1 Introduction
- 3.2 Safety On Site
- 3.3 INSTALLATION OVERVIEW
- 3.4 SITE POWER
- 3.5 REPEATER UNPACKING AND INSPECTION
- 3.6 SUGGESTED TOOL LIST
- 3.7 ANTENNA INSTALLATION
- 3.8 REPEATER CABINET INSTALLATION
- 3.9 CABLE CONNECTIONS (see Figure 3 - 2)
- 3.10 POST-INSTALLATION INSPECTION/TEST
- 3.11 Post Installation Inspection/Test Form
- Section 4 Turn-Up and Testing
- 4.1 General
- 4.2 Test Equipment Required
- 4.3 Repeater Provisioning
- 4.4 Field Tests
- 4.5 Connect Repeater System to NMC
- 4.6 Field Test Report
- Section 5 Operation
- 5.1 GENERAL
- 5.2 Control and Communication
- 5.3 Modes of Operation
- 5.4 GRAPHICAL USER INTERFACE (GUI)
- 5.5 GUI Menu Descriptions
- 5.5.1 Status Sub-Menu Breakdown
- 5.5.2 Configuration (Config) Sub-Menu Breakdown
- Figure 5 - 7 GUI Main Menu Config Drop-Down Menu
- Figure 5 - 8 Config Modulator Sub-Menu
- Figure 5 - 9 Repeater ID Screen
- Figure 5 - 10 Modulator Mode Screen
- Figure 5 - 11 Overlay Screen
- Figure 5 - 12 Delays Screen
- Figure 5 - 13 Modulator IP Screen
- Figure 5 - 14 VSAT Screen
- Figure 5 - 15 Repeater Output Level Screen
- Figure 5 - 16 Coupler Screen
- Figure 5 - 17 GPS Screen
- Figure 5 - 18 Temperature Screen
- Figure 5 - 19 Repeater Operating Mode Screen
- Figure 5 - 20 PPP Dial In Parameters Screen
- Figure 5 - 21 PPP Dial Out Parameters Screen
- Figure 5 - 22 PPP Misc Parameters Screen
- Figure 5 - 23 Site Screen
- 5.5.3 Alarms Sub-Menu Breakdown
- 5.5.4 NMS Users Sub-Menu Breakdown
- 5.5.5 System Parameters Menu
- Figure 5 - 28 Access to System Parameters Sub-Menu
- Figure 5 - 29 System Parameters Identification Screen
- Figure 5 - 30 System Parameters Access Control Screen
- Figure 5 - 31 System Parameters Network Parameters Screen
- Figure 5 - 32 System parameters SNMP Parameters Screen
- Figure 5 - 33 System Parameters System Time Screen
- Figure 5 - 34 System Heartbeat Time Screen
- Figure 5 - 35 System Parameters System Reset Screen
- Figure 5 - 36 System Parameters Upgrade Screen
- Figure 5 - 37 Upgrade Dialog Box (Sheet 1 of 2)
- 5.6 COMMAND LINE INTERFACE (CLI)
- 5.7 REPEATER OPERATING PROCEDURES
- 5.8 CONTROLS, INDICATORS, and CONNECTORS
- 5.8.1 Signal Processing Unit (SPU) Controls and Indicators
- 5.8.2 High Power Amplifier (HPA) Controls and Indicators
- 5.8.3 Power Distribution Unit (PDU) Front Panel Controls
- 5.8.4 VSAT Receiver Rear Panel Connectors
- 5.8.5 Up-Converter Rear Panel Connectors
- 5.8.6 Modulator Rear Panel Connectors
- 5.8.7 Main Controller Rear Panel Connectors
3EM21522AAAA Genera
l
Issue 1, March 2008 DTR-0200-SA-SIRIUS
1-9
1.7
REPEATER COMPONENTS LOCATION
The repeater enclosure cabinet contains field replaceable subassemblies called “Least
Replaceable Units (LRUs)” as listed in Table 1-8.
Figure 1 - 5
locates the repeater components including the LRUs.
The part number for the entire repeater enclosure cabinet with all electronics and
internal equipment is P/N 3EM04000AA.
Table 1-6 Repeater Test Ports
Repeater Out Forward Power Connector: N-type, female, 50 ohms, Coupling: -50 dB
Repeater Out Reflected Power Connector: N-type, female, 50 ohms, Coupling: -40 dB
HPA RF Monitor Connector: N-type, female, 50 ohms, Coupling: -50 dB
Upconverter RF Out Monitor Connector: SMA, female, 50 ohms, Coupling: -20 dB
Table 1-7 Repeater Test Modes
CW Signal COFDM spectrum replaced by a single carrier 4kHz aside from the
center frequency. The RMS level of the single carrier is equivalent to
average RMS level of normal COFDM spectrum. The signal is
intended for testing of in-band signal-to-noise ratio.
Notch Signal Movable group-of-carriers hole for test of intermodulation and quanti-
zation noise
PRBS Signal Empty DARS frames (PRBS sequence)
Table 1-8 Repeater Least Replaceable Units (LRUs)
Signal Processing Unit (SPU)
Refer to Appendix B
for part numbers
High Power Amplifier (HPA)
RF Output Coupler
RF Detector (Two; one forward, one reflected)
Cabinet Exhaust Fan (two exhaust fans under roof)
Cabinet Exhaust Fan Relay
Cabinet Intake Fan (two intake fans in rear door)
Cabinet Intake Fan Relay
PDU Circuit Breakers