SYSTEM CONFIGURATIONS
At the selected site the repeater can be mounted one of three ways:
ground mount
roof mount
shelf mount
The repeater electrical and physical configuration is the same for either mounting.
1.6
TERRESTRIAL REPEATER TECHNICAL SPECIFICATIONS
Table 1-1 Physical, Electrical, and Environmental Specifications
Weight Approx. 121 kg (266 lbs.)
Dimensions 60.10 x 102.55 x 67.63 cm / 26.81 x 36 x
40.38 x 26.63 in.
Cooling Forced Air
Power Requirements 188-250VAC, 208 VAC NOMINAL, 57-63 HZ
Power Consumption 2.0 KW, TYPICAL
UPS Duration For Main Controller 5 minutes
Operating Temperature -25ºC to +55ºC / -13ºF to +131ºF
Storage Temperature -50ºC to +65ºC / -58ºF to +149ºF
Humidity 95% Non-condensing
Ratings/Circuit Breaker Max Effective Load/Circuit Breaker
CB1 – SPU: 240V, 5A – 1.20kW
@ MAX 55ºC Max current 0.75A
CB2 - HPA: 240V, 25A – 6.00 kW
@ MAX 55ºC Max current 12.5A
CB3 - FANS: 240V, 5A – 1.20 kW
@ MAX 55ºC
4 fans, 80W each – 320W total
Max. current 1.5A
CB4 - EXTERNAL
HEATER:
120V, 5A – 0.240 kW
@ MAX 55ºC
Max. power 200W
Max. current 1.7A
CB5 - AUXILIARY
POWER:
120V, 10A – 0.600
kW @ MAX 55ºC Max. current 5A
CB6 – INTERNAL
HEATER:
240V, 5A – 1.20 kW
@ MAX 55ºC
2 Heaters 500W (nominal)
Max total. current @ 240VAC, 4.2A
CB0 – MAIN
CIRCUIT BREAKER:
LINE 1 - 240V, 32A
@ MAX 55ºC
LINE 2 - 240V, 32A
@ MAX 55ºC
NEUTRAL - 32A
@ MAX 55ºC
Max. load per Line and Neutral:
LINE 1: Max current 25.7A
LINE 2: Max current 19A
NEUTRAL: Max current 6.7A