User's Manual Part 1
Table Of Contents
- Instruction Book Introduction
- Customer Service
- Technical Assistance Center
- Sections 1-6
- Section 1 General
- Section 2 Functional Description
- 2.1 General
- 2.2 System Functional Overview
- 2.3 Main Functions
- 2.3.1 Signal Processing Unit (SPU) Sub-assembly
- Figure 2 - 2 Signal Processing Unit (SPU)
- Figure 2 - 3 Sirius Signal Processing Unit (SPU) Functional Block Diagram
- Figure 2 - 4 VSAT (L-Band) Receiver Panel
- Figure 2 - 5 Modulator Module
- Figure 2 - 6 Up-Converter Module Panel
- Figure 2 - 7 Controller Board Panel
- Figure 2 - 8 Main Controller Board Functional Block Diagram
- Figure 2 - 9 Uninterruptible Power Supply (UPS)
- 2.3.1 Signal Processing Unit (SPU) Sub-assembly
- 2.4 High Power Amplifier (HPA)
- 2.5 S-Band Output Filter
- 2.6 Output Coupler
- 2.7 Power Distribution
- 2.8 Junction Box Assembly
- Section 3 Installation
- 3.1 Introduction
- 3.2 Safety On Site
- 3.3 INSTALLATION OVERVIEW
- 3.4 SITE POWER
- 3.5 REPEATER UNPACKING AND INSPECTION
- 3.6 SUGGESTED TOOL LIST
- 3.7 ANTENNA INSTALLATION
- 3.8 REPEATER CABINET INSTALLATION
- 3.9 CABLE CONNECTIONS (see Figure 3 - 2)
- 3.10 POST-INSTALLATION INSPECTION/TEST
- 3.11 Post Installation Inspection/Test Form
- Section 4 Turn-Up and Testing
- 4.1 General
- 4.2 Test Equipment Required
- 4.3 Repeater Provisioning
- 4.4 Field Tests
- 4.5 Connect Repeater System to NMC
- 4.6 Field Test Report
- Section 5 Operation
- 5.1 GENERAL
- 5.2 Control and Communication
- 5.3 Modes of Operation
- 5.4 GRAPHICAL USER INTERFACE (GUI)
- 5.5 GUI Menu Descriptions
- 5.5.1 Status Sub-Menu Breakdown
- 5.5.2 Configuration (Config) Sub-Menu Breakdown
- Figure 5 - 7 GUI Main Menu Config Drop-Down Menu
- Figure 5 - 8 Config Modulator Sub-Menu
- Figure 5 - 9 Repeater ID Screen
- Figure 5 - 10 Modulator Mode Screen
- Figure 5 - 11 Overlay Screen
- Figure 5 - 12 Delays Screen
- Figure 5 - 13 Modulator IP Screen
- Figure 5 - 14 VSAT Screen
- Figure 5 - 15 Repeater Output Level Screen
- Figure 5 - 16 Coupler Screen
- Figure 5 - 17 GPS Screen
- Figure 5 - 18 Temperature Screen
- Figure 5 - 19 Repeater Operating Mode Screen
- Figure 5 - 20 PPP Dial In Parameters Screen
- Figure 5 - 21 PPP Dial Out Parameters Screen
- Figure 5 - 22 PPP Misc Parameters Screen
- Figure 5 - 23 Site Screen
- 5.5.3 Alarms Sub-Menu Breakdown
- 5.5.4 NMS Users Sub-Menu Breakdown
- 5.5.5 System Parameters Menu
- Figure 5 - 28 Access to System Parameters Sub-Menu
- Figure 5 - 29 System Parameters Identification Screen
- Figure 5 - 30 System Parameters Access Control Screen
- Figure 5 - 31 System Parameters Network Parameters Screen
- Figure 5 - 32 System parameters SNMP Parameters Screen
- Figure 5 - 33 System Parameters System Time Screen
- Figure 5 - 34 System Heartbeat Time Screen
- Figure 5 - 35 System Parameters System Reset Screen
- Figure 5 - 36 System Parameters Upgrade Screen
- Figure 5 - 37 Upgrade Dialog Box (Sheet 1 of 2)
- 5.6 COMMAND LINE INTERFACE (CLI)
- 5.7 REPEATER OPERATING PROCEDURES
- 5.8 CONTROLS, INDICATORS, and CONNECTORS
- 5.8.1 Signal Processing Unit (SPU) Controls and Indicators
- 5.8.2 High Power Amplifier (HPA) Controls and Indicators
- 5.8.3 Power Distribution Unit (PDU) Front Panel Controls
- 5.8.4 VSAT Receiver Rear Panel Connectors
- 5.8.5 Up-Converter Rear Panel Connectors
- 5.8.6 Modulator Rear Panel Connectors
- 5.8.7 Main Controller Rear Panel Connectors
OPERATION 3EM21522AAAA
DTR-0200-SA-SIRIUS Issue 1, March 2008
5-48
5.8.7
Main Controller Rear Panel Connectors
The Main Controller rear panel has 20 connectors;
MODEM
, spare (3),
FWD RF
DETECTOR, REFL RF DETECTOR, PA CONTROL, TEMP.SENSOR, STATUS IN,
RELAY CONTROL, 10MHZ, 1PPS, ASI A, ASI B, ETHERNET 10/100/1000 BASE T (4),
GPS ANT, DIAL-UP
. See Figure 5 - 53.
Figure 5 - 53 Main Controller Rear Panel
CONNECTOR COMMENTS
MODEM Not connected
FWD RF DETECTOR Connects to RF forward power detector for RF monitoring
REFL. RF DETECTOR Connects to RF reflected power detector for RF monitoring
PA CONTROL Connects to HPA Control I/F
TEMP.SENSOR Connects to PDU
STATUS IN Connected to Status Cable inside repeater and indicates Door Status
RELAY CONTROL
Connected to Relay Cable inside repeater and indicates Relay Status
10 MHZ Not connected
1 PPS Not connected
ASI A Not connected
ASI B Connected to VSAT RX ASI OUT 2
ETHERNET 10/100 BASE T There are four Ethernet connectors. Any one of the four must connect
by cable to the Modulator back panel Ethernet connector. This pro-
vides communication between the Modulator and Main Controller.
The remaining three Ethernet connectors connect to external equip-
ment such as a PC (for troubleshooting, parameter monitoring, etc.).
GPS ANT Connects to GPS Antenna cable.
DIAL-UP Phone cable connection