User's Manual Part 1

Table Of Contents
OPERATION 3EM21522AAAA
DTR-0200-SA-SIRIUS Issue 1, March 2008
5-34
5.7.1.1
Local Operation
For repeater local control (during initial setup and/or maintenance sessions, etc.) and
status information, a PC can be connected to the LAN and established via the Ether-
net (RJ45) port which provides access to the Web and GUI interface. This is the pre-
ferred method.
An alternate access method is via the RS-232 (DB9) serial port using the Command
Line Interface (CLI) protocol.
The RS-232 provides access to CLI and allows the oper-
ator to perform initial setup and/or troubleshooting when network connectivity may
not be a
vailable or desired.
5.7.1.2
Setting to Local Operating Condition
1. Coordinate with the NMC operator.
2. Press the SPU front panel LOCAL/REMOTE switch to change to the
LOC
AL position (see Figure 5 - 41).
3. Wait for the LOCAL LED to switch from Red to Green (approximately 2.5
minutes).
Figure 5 - 41 SPU Front Panel Local/Remote Switch
SYS ALARM
OUT POWER
ALARM
CABINET
HPA
LOCAL REMOTE RESET
DTR-1039A
04/20/07
REFL Power
AC MAIN
AC
UPCONVERTER
SPU
ALARMS
MODULATION
INPUT INTERFACE
1PPS/10MHZ STATUS
SFN TIMING
SYNCH
STREAM LOCK
TEMPERATURE