Submittal Sheet

SPECIFICATION
Sioux Chief 696R series Ox Box re-rated drain box shall be used where
necessary in plumbing systems. Box shall allow for mounting with drainage
line from bottom, mounted on stud. Metal support bracket shall install
into top track of box for added support. Drain box shall have a ⅝" integral
testable nipple on knockout. Drain connection shall be 2".
MATERIALS
outlet box: ABS
frame: re-rated ABS
frame extension*: re-rated ABS
bracket: galvanized steel
re-guard: intumescent material
* 696-EX available separately. Used with two layers of drywall for 2-hour specications.
INSTALLATION
Stud construction can be non-load bearing or load bearing. Wood or metal
stud construction, max 100 in² of penetrations per 100 ft² of wall.
CERTIFICATIONS/APPROVALS
Listed by UPC/IAPMO to meet UPC
Conforms to IPC
Listed by Warnock Hersey to meet:
ASTM E-814, CAN/ULC S115
2 hours (F), 1½ hours (T) for 2-hour design
1 hour (F), 31 minutes (T) for 1-hour design
ASTM E-119, UL 1479
System design number:
SC/WA120 , W/N 14409
DIMENSIONS
frame width "A:
frame height "B:
frame opening width 3⅝"C:
frame opening height 5⅛"D:
rough-in box inner width 4"E:
rough-in box overall depth "F:
rough-in box inner height "G:
secondary knockout 1H:
7
11
"
drain connection 2" DWVI:
bracket length 18"J:
bracket width ⅝"K:
bracket thickness 18 gauge
696R3
696R series Ox Box
FIRE-RATED DRAINAGE BOX
J
K
A
C
BD
E
F
G
H
I
696R3
ACCESSORIES
696-EX frame extension
Sioux Chief Manufacturing Company • tel: 1-800-821-3944 • www.siouxchief.com • fax: 1-800-758-5950
Item # Submitted �����������������������������������
Job Name �����������������������������������������
Location ������������������������������������������
Engineer ������������������������������������������
Contractor ����������������������������������������
PO# �������������������� TAG ���������������������
12-08

Summary of content (1 pages)