Datasheet
•AC• S92AP
92x92x25.5mm / 3.6x1inch
35~21 CFM
Axial Plastic Impelle
r
Rated
Volt
Voltage
Ran
g
e
Freq
Input
Power
Ref.
Speed
Max.Airflow Max.Static Pressure
Noise
Level
PQ
Model No VAC VAC Hz Watt RPM CFM m3/min Inch/H2O mm db(A)
S92AP-11-1** 115 100~120 50/60 15/13 2500/3000 30/35 0.8/1 0.16/0.20 4.06/5.08 30 2/1
S92AP-11-2** 115 100~120 50/60 12/10 2100/2300 25/27 0.7/0.8 0.13/0.14 3.3/3.56 22 4/3
S92AP-11-3** 115 100~120 50/60 8/6 1800/1900 21/22 0.6/0.6 0.09/0.10 2.29/2.54 19 6/5
S92AP-22-1** 230 200~240 50/60 15/13 2500/3000 30/35 0.8/1 0.16/0.20 4.06/5.08 30 2/1
S92AP-22-2** 230 200~240 50/60 12/10 2100/2300 25/27 0.7/0.8 0.13/0.14 3.3/3.56 22 4/3
S92AP-22-3** 230 200~240 50/60 8/6 1800/1900 21/22 0.6/0.6 0.09/0.10 2.29/2.54 19 6/5
S92AP-4-1** 24 24~28 50/60 15/13 2500/3000 30/35 0.8/1 0.16/0.20 4.06/5.08 30 2/1
S92AP-11/22-1**
dual voltage
115
230
100~120
200~240
50/60 15/13 2500/3000 30/35 0.8/1 0.16/0.20 4.06/5.08 30 2/1
z ** = "WB" for wire lead type Ball bearing, or "TB" for terminal type Ball bearing
z 100, 200, 240V or special voltages 12, 24, 28, 38, 42, 48, 380, 440, 480V... 50/60Hz, & any voltages available.
z Dual speed High/Medium 1/2, Medium/Low 2/3 available on request.
z Sinwan reserves the ri
g
ht to chan
g
e data and improve electrical & mechanical desi
g
n without notice.
Motor Type: Shaded pole induction, inner rotor, 1-phase
Burnout Protection: Impedance protected
IP Protection:
Frame: Aluminum die cast, black color(AP)
Impeller: 5 blades, glass fiber reinforced plastic, rated
UL94V-0
Bearing: Two ball bearings. or sleeve bearing
Rotation: CCW view from label side
Connection: Wire lead or terminal flat pin connecting
Weight: 290 g (0.64 Lbs)
Dielectric Strength: Over 1 min.at 1,500 VAC, 0.5mA, 50/60 Hz
Insulation Resistance: Over 100 MΩ at DC 500V
Signal Output:
Operating Temp: Non-condensing ball bearing (-20C~+80C),
sleeve (-10~+45C)
Storage Temp:
Life Expectancy: Ball bearing 80K hours at 45C, 50K hours at
60C