2.5 Conversion Detail
The SingleTact electronics interface measures the capacitive sensor with 16-bit precision. This is
scaled to a 10-bit digital (2V analog) output using the following calculation:
Figure 8 Digital Output
The digital scaling value is a 16-bit value stored at register locations 10 and 11 (see Table 2). For
increased precision (within a given sensor’s valid operating range) the digital scaling value can be
adjusted in 0.01 increments. A value of 100 represents unity scaling (100 x 0.01).
The internal capacitance to digital converter (CDC) operates at 140 to 4000 Hz depending on the
capacitance sensor settings (in particular the number of accumulations).
Each time the CDC completes a measurement
OVER
PRESSURE
NEGATIVE
PRESSURE
VALID
RANGE
Force or Pressure
Analog Output
0
255
767
1023
FSR
0
π‘Ίπ’Šπ’π’ˆπ’π’†π‘»π’‚π’„π’• 𝑢𝒖𝒕𝒑𝒖𝒕 =
π‘Ήπ’‚π’˜ π’„π’‚π’‘π’‚π’„π’Šπ’•π’‚π’π’„π’† βˆ’ π‘©π’‚π’”π’†π’π’Šπ’π’† π’„π’‚π’‘π’‚π’„π’Šπ’•π’‚π’π’„π’†
π‘«π’Šπ’ˆπ’Šπ’•π’‚π’ π’”π’„π’‚π’π’Šπ’π’ˆ 𝒗𝒂𝒍𝒖𝒆
+ πŸπŸ“πŸ“