User Manual

pg. 14
Copyright © 2017- www.SingleTact.com
The frame synchronization output (Frame Sync, Figure 4) goes high each time a new measurement is
available. This can be used to synchronize the I
2
C communications channel to the capacitance
sensor.
Alternatively, the sensor might be polled as quickly as possible over I
2
C. Since the frame index
increments with each frame it can be used to identify duplicate or missing data readings.
2.6 Product Categories
Standard sensors will perform typically to their specified force range.
The separately available, generic electronics interface from PPS is suitable for use with the Standard
sensors. With a standard sensor fitted and loaded to its specified maximum force (e.g. 45N for a 45N
sensor) the scaling factor may be configured via the I
2
C bus to generate an I
2
C sensor value equal to
511 and equivalent analog output of 1.5V to ensure the sensor is operating within its valid range.
Calibrated sensors offer improved accuracy and linearity over the Standard sensors and come as a
matched sensor plus electronics interface board providing a pre-configured, calibrated linear output
for the specified sensor range, e.g. for an input force of 0 to 10N a 10N calibrated sensor will output a
linear I
2
C range of 0 to 511 and equivalent analog output of 0.5V to 1.5V.
To maintain calibration, calibrated electronics + sensor combinations as shipped should be
maintained as matched pairs.
To implement multiple sensor solutions multiple sensor interface boards can be connected to a single
I
2