2.2 Analog Interface
The analog output swings from 0 to 2V, with the valid working output ranging from 0.5V to 1.5V as
shown in Figure 5.
As pressure increases beyond the full scale range (FSR) the output will increase to 2V and then limit.
The sensor should be unloaded at power on to allow the sensor’s baseline to be registered correctly.
NOTE: An output below 0.5V may indicate negative pressures, which occur when the sensing area is
under tension. This should be avoided since it can damage the internal structure of the sensor.
NOTE: Sensor over pressure should be limited to less than 3x FSR to avoid damaging the sensor.
Figure 5 Analog Output
OVER
PRESSURE
NEGATIVE
PRESSURE
VALID
RANGE
Force or Pressure
Analog Output
0V
0.5V
1.5V
2.0V
FSR
0