5.4.1 Command Matrix Settings
The following list defines the sets of numbers and the actions they represent. Use these values to program the
command matrix.
Value Relay Action
0 Turn relay off
1 Turn relay on
2 No change
3 Turn relay on for 1/2 second
4 Turn relay on for 1 second
5 Turn relay on for 1 1/2 seconds
6 Turn relay on for 2 seconds
7 Turn relay for 2 1/2 seconds
+ Values over 7 default to 2
Value Audio Action
0 Off--mute audio in and out
1 No change
2 Monitor audio from inputs / ALC active
3 Send audio to outputs / ALC active--telephone sends audio
4 Send audio to outputs/ ALC frozen--telephone sends audio
5 Send audio to outputs / ALC inactive--programmable fixed gain
+ Values over 5 default to 1
Value Slate Action
0 Off--no tone
1 Shortest tone
... (factory setting 4)
8 Longer tone
9 Longest tone
Value Alarm Action
0 Off--do not trip alarm
1 On--trip alarm
+ Values over 1 default to 0
Value Read Status Action
0 Off--do not report status of input
1 On--report state of input
+ Values of 2 or more default to 1
DAI-2 Programming page 5. 8