Specifications
Section 3 — Specifications
3.1 General
Output Relay Operation Output relay contact closes within one second after
audio becomes present and remains closed as long
as
audio is present. Output relay contact opens at the
end of an adjustable delay period after audio
becomes absent.
Delay Range 7 seconds to approximately 4.5 minutes.
(factory adjusted to approximately 4.5 minutes)
Indicators 1. Audio Present (Green LED)
2. Relay Closed (Green LED)
3.2 Audio Input
Number Of Audio Inputs 2
Input Type Actively Balanced
Input Impedance 60 K Ohms
Sensitivity (For Relay Closure) -16 DBv
3.3 Relay Output
Output Type 1 Form "A" (SPST) Contact, Floating
Contact Ratings 120 Volts AC, 5 Amps Resistive/2 Amps Inductive
Version 2.00 Specifications page 3.1