Specifications

Appendix A –– Programming Address Table
- Programming -
Address Description Section Default Current Alternate Use / Notes
RFC-1 Programming Address Table with RAK-2 Default Settings page A.22
0996 Hardware version 6.10.2 3 ____ __________________________
0997 Telemetry settling time 6.3.8 2 ____ __________________________
0998 Telemetry leading zero suppression 6.3.7 1 ____ __________________________
0999 Telephone dialing mode (tone/pulse) 6.8.5 1 ____ __________________________
1000 Inactive system timeout 6.10.3 0 ____ __________________________
1001 Answer ring number 5.6.2 2 ____ __________________________
1002 Communication mode (data/voice) 6.8.9 3 ____ __________________________
1003 Telephone call alarm message duration 6.5.5 2 ____ __________________________
1004 Telephone call pause between calls duration 6.5.5 4 ____ __________________________
1005 Serial data protocol and baud rate 6.8.10 0 ____ __________________________
1006 Control relay minimum operate time 6.5.3 1 ____ __________________________
1007 Action sequence delay between steps 6.5.4 1 ____ __________________________
1008 Action sequence at power-on action (power failure alarm) 6.4.8 10 ____ __________________________
1009 Telemetry alarm system enable/disable 6.6.6 0 ____ __________________________
1010 Telemetry auto-scan stop channel – tens digit 6.7.8 0 ____ __________________________
1011 Telemetry auto-scan stop channel – ones digit 6.7.8 7 ____ __________________________
1012 Telemetry auto-scan data interval 6.7.7 2 ____ __________________________
1013 Telemetry alarm scan interval and sequence 6.6.7 0 ____ __________________________
1014 Telephone ring detection sensitivity 6.8.8 3 ____ __________________________
1015 Shared memory selector (telemetry labels/time triggers) 6.7.3 6 ____ __________________________
1016 Security code failure lockout time 6.9.3 1 ____ __________________________
1017 Daylight savings time auto-adjust enable/disable 6.4.4 0 ____ __________________________
1018 Clock speed adjustment—value 1 6.4.5 8 ____ __________________________
1019 Clock speed adjustment—value 2 6.4.5 0 ____ __________________________
1020 Default telemetry units or status format—value 1 6.3.2 0 ____ __________________________
1021 Default telemetry units or status format—value 2 6.3.2 3 ____ __________________________
1022 Default full scale and decimal point 6.3.3 2 ____ __________________________
1023 Default linear/log/indirect and auto relay 6.3.4 0 ____ __________________________