Owner`s manual
22
Method of installation
Heat pump can be installed on the floor on a concrete base using spacer screws or on a metal frame using
rubber feet. Please ensure the unit is installed horizontally.
1) Prepare a foundation for outdoor unit installation.
2) Build concrete pillars, where feet of the outdoor unit will stand. Respect all principles for construction
work and security.
3) Lay a drainage hose for condensate drainage and cover with gravel to the height of about 200 mm.
4) Lay copper piping and communication cables in a protective tube into the requested place and
positioning.
5) Put additional gravel up to the top of the hole and align with terrain.
6) Fix feet of outdoor unit to the foundation using suitable screws.
Protective tube for piping and cables
Gravel ground
- height min. 600 mm
Drainage
hose