Owner`s manual
19
Operation range
Capacity specifications
CAPACITY SPECIFICATIONS
Ambient temperature (A) / Output water temperature (W) (°C) *
Model
SHP-140 SHP-180
A20/W35
Heating capacity (kW) 18,28 22,32
Power input (kW) 3,28 3,83
COP (-) 5,58 5,82
A10/W35
Heating Capacity (kW) 15,55 17,88
Power Input (kW) 3,28 3,90
COP (-) 4,75 4,58
A7/W35
Heating Capacity (kW) 14,73 16,79
Power Input (kW) 3,28 3,94
COP (-) 4,49 4,26
A2/W35
Heating Capacity (kW) 11,38 13,27
Power Input (kW) 3,06 3,77
COP (-) 3,72 3,52
A-7/W35
Heating Capacity (kW) 10,30 11,09
Power Input (kW) 3,17 3,85
COP (-) 3,25 2,88
A-15/W45
Heating Capacity (kW) 8,81 10,43
Power Input (kW) 4,09 4,95
COP (-) 2,16 2,11
A35/W12
Cooling Capacity (kW) 10,90 12,50
Power Input (kW) 3,41 4,46
EER (-) 3,20 2,80
* Values measured according to the Standard EN 14511-2:2012 / EHPA.
Measurement contains also defrosting cycle.
Outdoor temperature (°C)
Water temperature (°C)