Owner`s manual
11
Specifications
This operation manual is valid exclusively for the following models of heat pump:
Model
Outdoor unit SHP-140ERC SHP-180ERC
Indoor unit SHP-140IRC SHP-180IRC
Capacity / Power input / Current / COP kW/kW/A/- 14,70/3,28/11,0/4,49 16,79/3,94/11,0/4,26
Range of
operation
temperatures
Heating °C -20~40 -20~40
Cooling °C 18~40 18~40
DHW (domestic hot water) °C -20~40 -20~40
Range of output water temperature °C 12~65 12~65
Energy class - A A
Indoor unit power supply V/Ph/Hz 380/3/50 380/3/50
Starting current A 59 59
Electric heater
Number pcs 1 1
Power input kW 3,0 3,0
Operation current A 4,6 4,6
Compressor
Model - ZH13KVE-TFD ZW61KSE
-
TFP
-
542
Brand - Copeland EVI Copeland EVI
Type SCROLL SCROLL
Number pcs 1 1
Power input W 3480 4900
Rated current (RLA) A 8,7 9,8
Starting current (LRA) A 64 59
Water pump
Model
STRATOS PARA 25/1-
8
STRATOS PARA 25/1-
8
Power input W 140 140
Min/max discharge m 1/8 1/8
Refrigerant
Type - R407c R407c
Refrigerant charge kg 8,0 8,0
Fan
Motor type M3G084-GF M3G084-GF
Power input W 182,0 182,0
Speed r/min 655,0 655,0
Max. pressure Pa 45,0 45,0
Air flow m
3
/h 4995,0 4995,0