Service manual

11
PRODUCT
4.2.3 Floor ceiling type
Model
Heat pump MC-F09AI MC-F12AI
Product Code CN610N0010 CN610N0020
Capacity
Cooling kW 2.5 3.5
Heating kW 2.8 3.85
Power supply V-Ph-Hz 220~240-1-50 220~240-1-50
Motor power input kW 0.055 0.055
Air ow volume
m
3
/h 650.0 650.0
CFM 383.0 383.0
Sound pressure level(H/L) dB(A) 40/36 40/36
Fan motor
Output kW 0.3 0.3
Running current A 0.297 0.297
Connecting pipe
Gas inch 3/8″(9.52mm)
3/8”(9.52mm)
Liquid inch 1/4″(6.35mm) 1/4″(6.35mm)
Connection method Flare Connection Flare Connection
Drain pipe
External dia. mm 17 17
Thickness mm 1.75 1.75
Outline dimension W×D×H mm 1220×700×225 1220×700×225
Package dimension W×D×H mm 1343×823×315 1343×823×315
Net Weight kg 40.0 40.0
Gross weight kg 50.0 50.0
Loading quantity
20'GP 48 48
40' GP 96 96
40' HQ 96 96
Notes:
a. The rated cooling capacity data is measured under the following work condition: Indoor Temperature is 27
DB,
1 9
WB. Outdoor Temperature is 35
DB.The rated heating capacity data is measured under the following work
condition: Indoor Temperature is 20
DB. Outdoor Temperature is 7
DB, 6
WB.
b. The data will change with the change of products. Refer to those parameters listed on nameplate.
c. Noise was tested in semi-silenced room, so the actual noise value will be a little higher for change of ambient.
9