Service manual
6
PRODUCT
4 PRODUCT DATA
4�1 Product data of outdoor
Model
Heat pump MC-E36AI MC-E42AI
Product Code CN860W0010/CN860W0011 CN860W0020
Capacity
Cooling kW 9.789 11.6
Heating kW 11 13
Capacity adjustment range % 23% ~ 150% 19%~ 150%
EER kW/kW 3.23 3.23
COP kW/kW 3.65 3.67
Power supply V-Ph-Hz 220~240-1-50 220~240-1-50
Refrigerant
Type R410a R410a
Charge volume kg 3.6 4.8
Compressor
Brand MITSUBISHI MITSUBISHI
Type DC inverter rotor type DC inverter rotor type
Quantity 1 1
Moisture protection IP×4 IP×4
Wiring connection Area*quantity mm
2
6*3 6*3
Connecting pipe Connection method Flare Connection Flare Connection
Sound pressure level dB(A) 54 54
Outline dimension W×D×H mm 950×412×840 1015×440×1103
Package dimension W×D×H mm 1100×450×905 1155×490×1220
Net weight kg 75 102
Gross weight kg 78 112
Maximum drive IDU NO. unit 4 5
Max. equivalent connection pipe length m 70 80
Loading quantity
20'GP 52 52
40' GP 108 48
40' HQ 108 48
Notes:
a. The rated cooling capacity data is measured under the following work condition: Indoor Temperature is 27
℃
DB,
1 9
℃
WB. Outdoor Temperature is 35
℃
DB.The rated heating capacity data is measured under the following work
condition: Indoor Temperature is 20
℃
DB. Outdoor Temperature is 7
℃
DB, 6
℃
WB.
b. The data will change with the change of products. Refer to those parameters listed on nameplate.
c. Noise was tested in semi-silenced room, so the actual noise value will be a little higher for change of ambient.
5